                                 Moving Iron AC Volt & Amp Meter 

• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 Degree.
• Ammeter with over scale x2, x3, x5 for 90 degree
• AC voltage direct connection 0-150V, 0-300V,0-500V, 0-600V or request.
• AC voltage PT connection 100, 110, 115, 120 v ac or request.
• AC current direct 1, 2.5, 5, 10, 20, 25, 30, 40, 50, 100A.
• AC current transformers connection / 1 A or / 5 A with 2 times over scale as a 

standard or  option with 3 times over scale, 5 times over scale
                                                                                            
                           ÃÒÂÅÐàÍÕ´

                    Moving Coil with Rectifier AC Volt & Amp Meter

• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 Degree.
• CT / 1 A. or CT / 5 A

• AC voltage direct connection 0-150V, 0-300V,0-500V, 0-600V or request.
• AC voltage PT connection 100, 110, 115, 120V ac or request.
• AC current direct 1, 2.5, 5, 10, 20A.
• AC current transformers connection / 1 A or / 5 A.
• more detail see ordering information.

                                                                                                                                                                                                                                            ÃÒÂÅÐàÍÕ´

                                       AC Watt & Var Meter 

• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 degree.
• CT / 1 A. or CT / 5 A

• Input voltage direct 100V, 110, 230, 240, 380, 415, 440V or request.
• Input voltage PT connection 100, 110, 115, 120V ac or request.
• Input current CT / 1A or CT / 5A .
• and more detail see ordering information.
                                                                                                                        ÃÒÂÅÐàÍÕ´

                                     AC Power Factor Meter 

• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 %
• 90 Degree and 240 degree.
• CT / 1 A. or CT / 5 A.
• Input voltage direct 100V, 110, 230, 240, 380, 415, 440V or request.
• Input voltage PT connection 100, 110, 115, 120V ac or request.
• Input current CT / 1A or CT / 5A .
• and more detail see ordering information.
                                                                                                                                                            ÃÒÂÅÐàÍÕ´

     Moving Iron AC Amp Meter with Max Demand or Max Demand + Relay output

• Front Dimension 96x96mm Or 72x72mm. Or 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 3.0 %.
• 90 Degree.
• Ammeter with over scale 120%
• Relays output for Demand Control or Energy Managements
 
• CT connection /1A or /5A with 20% over scale as a standard.
• With relays output for demand control or energy managements.   
• The relays perform with time delay 1second approximately fixed.
• Alarm trip point working range 20-100% of range ±1% added to the MDI accuracy.
• Free contact output as single pole change over with relay rating
  AC 250V 5A non inductive load or 24V DC 2A resistive load.
• more detail see ordering information.
                                                                                                                                                             ÃÒÂÅÐàÍÕ´

         Moving Coil Rectifier Volt & Amp Meter with Maximum Pointer

• Front Dimension 96x96mm Or 72x72mm. Or 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 <
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy± 1.5 %.
• 90 Degree or 240 Degree.

• AC voltage 0-150V, 0-300V,0-500V, 0-600V or request.
• AC voltage PT connection 100, 110, 115, 120V or request.
• AC current direct 1, 2.5, 5, 10, 20A.
• AC CT connection / 1 A or / 5 A.
• more detail see ordering information.
                                                                                                                       ÃÒÂÅÐàÍÕ´

                               Moving Coil Frequency Meter 

• Front Dimension 144x144mm, 96x96mm, 72x72mm, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.0 % Or customize
• 90 Degree and 240 degree.

• Direct connection 50V, 100V, 220V, 380V, 415V, 440V or request.
• Frequency range 45-55Hz, 47-53Hz , 45-65Hz, 55-65Hz, 44-56Hz, 54-66Hz,
  450-550Hz., 450-650Hz., 550-650Hz.
• more detail see ordering information.

                                                                                                                      ÃÒÂÅÐàÍÕ´

                              Vibration Reed Frequency Meter 

• Front Dimension 144x144mm, 96x96mm, 72x72mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy± 1.0 % Or customize.
• Vibration reed movements

Direct connection 50V, 100V, 220V, 380V, 415V, 440V or request.
• Frequency range 45-55Hz, 47-53Hz, 55-65Hz, 57-63Hz, 54-66Hz,
  450-550Hz., 450-  650Hz., 550-650Hz.
• more detail see ordering information.
                                                                                                                      ÃÒÂÅÐàÍÕ´

                              Moving Coil DC Volt & Amp Meter

• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 degree.

• DC voltage direct connection 0-150V, 0-300V or request.
• DC current direct 1, 3, 5, 10, , 20, 30A or see ordering.   
  ( For DC48 dimension 48x48mm. max direct current is 5 A.)
• DC current with shunt resistor connection 60mV, 75mV,
  150mV, 300mV or     request.
• DC current direct 100uA, 300uA, 1mA, 5mA, 10mA, 20mA,    
 
30mA, 50mA, 75mA, 100 mA, 150mA, 4…20mA or see ordering.
• more detail see ordering information.                                                                                                                                                                                      
        ÃÒÂÅÐàÍÕ´

                                 Hour run or Elapsed time Meter 

• Front Dimension 96x96mm Or 72x72mm. Or 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Display Range 99999.99
• Hi resolution 0.01
• Indication Cleary Even Power Failure

• Hour meter with direct connection 50V, 100V, 220V, 380V, 415V, 440V
  or request. Frequency operating 50 Hz. or 60 Hz..
• Option DC 24V
                                                                                                                                                                                                               ÃÒÂÅÐàÍÕ´

Hour run or Elapsed time Meter 

Front Dimension 72x72mm with front plate.
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
Polycarbonate, self extinguishing and drip-proof per UL94V-0
Rugged housing-non combustible, plastic-heat resistance.
Display Range 99999.99
Hi resolution 0.01
Indication Cleary Even Power Failure