Moving Iron AC Volt & Amp Meter
• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 Degree.
• Ammeter with over scale x2, x3, x5 for 90 degree
• AC
voltage direct connection 0-150V, 0-300V,0-500V, 0-600V or request.
• AC
voltage PT connection 100, 110, 115, 120 v ac or request.
• AC
current direct 1, 2.5, 5, 10, 20, 25, 30, 40, 50, 100A.
• AC
current transformers connection / 1 A or / 5 A with 2 times over
scale as a
standard or option with 3 times over
scale, 5 times over scale
ÃÒÂÅÐàÍÕ´ |
|
 |
Moving Coil with Rectifier AC Volt & Amp Meter
• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
• Polycarbonate, self extinguishing and drip-proof per UL94V-0
• Rugged housing-non combustible, plastic-heat resistance.
• Accuracy ± 1.5 % Or class1.0 Or customize.
• 90 Degree and 240 Degree.
• CT / 1 A. or CT / 5 A
• AC
voltage direct connection 0-150V, 0-300V,0-500V, 0-600V or request.
• AC
voltage PT connection 100, 110, 115, 120V ac or request. • AC
current direct 1, 2.5, 5, 10, 20A.
• AC
current transformers connection / 1 A or / 5 A. • more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
AC Watt & Var Meter
• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm. •
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy ± 1.5 % Or
class1.0 Or customize. • 90
Degree and 240 degree. • CT /
1 A. or CT / 5 A
• Input
voltage direct 100V, 110, 230, 240, 380, 415, 440V or request.
• Input
voltage PT connection 100, 110, 115, 120V ac or request.
• Input
current CT / 1A or CT / 5A .
• and more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
AC Power Factor Meter
• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm. •
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy ± 1.5 %
• 90
Degree and 240 degree. • CT / 1
A. or CT / 5 A.
• Input
voltage direct 100V, 110, 230, 240, 380, 415, 440V or request.
• Input
voltage PT connection 100, 110, 115, 120V ac or request.
• Input
current CT / 1A or CT / 5A .
• and more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Moving Iron AC Amp Meter with Max Demand or Max Demand + Relay
output
• Front
Dimension 96x96mm Or 72x72mm. Or 48x48mm. • DIN43700, DIN43802,
DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy ± 3.0 %. • 90
Degree. • Ammeter
with over scale 120% •
Relays output for Demand Control or Energy Managements
• CT
connection /1A or /5A with 20% over scale as a standard.
• With
relays output for demand control or energy managements.
• The
relays perform with time delay 1second approximately fixed.
• Alarm
trip point working range 20-100% of range ±1% added to the MDI
accuracy.
• Free
contact output as single pole change over with relay rating
AC 250V
5A non inductive load or 24V DC 2A resistive load.
• more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Moving Coil Rectifier Volt & Amp Meter with Maximum Pointer
• Front
Dimension 96x96mm Or 72x72mm. Or 48x48mm. •
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 < •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy± 1.5 %. • 90
Degree or 240 Degree.
• AC
voltage 0-150V, 0-300V,0-500V, 0-600V or request.
• AC
voltage PT connection 100, 110, 115, 120V or request.
• AC
current direct 1, 2.5, 5, 10, 20A.
• AC CT
connection / 1 A or / 5 A.
• more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Moving Coil Frequency Meter
• Front Dimension 144x144mm, 96x96mm, 72x72mm, 48x48mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy ± 1.0 % Or
customize • 90
Degree and 240 degree.
• Direct
connection 50V, 100V, 220V, 380V, 415V, 440V or request.
•
Frequency range 45-55Hz, 47-53Hz , 45-65Hz, 55-65Hz, 44-56Hz,
54-66Hz,
450-550Hz., 450-650Hz., 550-650Hz.
• more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Vibration Reed Frequency Meter
• Front Dimension 144x144mm, 96x96mm, 72x72mm.
• DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy± 1.0 % Or
customize. •
Vibration reed movements
• Direct
connection 50V, 100V, 220V, 380V, 415V, 440V or request.
•
Frequency range 45-55Hz, 47-53Hz, 55-65Hz, 57-63Hz, 54-66Hz,
450-550Hz., 450- 650Hz., 550-650Hz.
• more
detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Moving Coil DC Volt & Amp Meter
• Dimension 144x144, 120x120, 96x96, 80x80, 72x72, 48x48mm. •
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. •
Accuracy ± 1.5 % Or
class1.0 Or customize. • 90
Degree and 240 degree.
• DC
voltage direct connection 0-150V, 0-300V or request.
• DC
current direct 1, 3, 5, 10, , 20, 30A or see ordering.
( For DC48
dimension 48x48mm. max direct current is 5 A.)
• DC
current with shunt resistor connection 60mV, 75mV,
150mV, 300mV or request.
• DC
current direct 100uA, 300uA, 1mA, 5mA, 10mA, 20mA,
30mA, 50mA,
75mA, 100 mA, 150mA, 4…20mA or see ordering.
• more detail see ordering information.
ÃÒÂÅÐàÍÕ´ |
|
 |
Hour run or Elapsed time Meter
• Front
Dimension 96x96mm Or 72x72mm. Or 48x48mm. •
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89 •
Polycarbonate, self extinguishing and drip-proof per UL94V-0 • Rugged
housing-non combustible, plastic-heat resistance. • Display
Range 99999.99 • Hi
resolution 0.01 •
Indication Cleary Even Power Failure
• Hour
meter with direct connection 50V, 100V, 220V, 380V, 415V, 440V
or
request. Frequency operating 50 Hz. or 60 Hz..
• Option
DC 24V
ÃÒÂÅÐàÍÕ´ |
|
  |
Hour run or Elapsed time Meter
•
Front Dimension 72x72mm with front
plate.
•
DIN43700, DIN43802, DIN43718, IEC1010, IEC473, IEC51, BS89
•
Polycarbonate, self extinguishing and drip-proof per UL94V-0
•
Rugged housing-non combustible, plastic-heat resistance.
•
Display Range 99999.99
•
Hi
resolution 0.01
•
Indication Cleary Even Power
Failure
ÃÒÂÅÐàÍÕ´ |
|