TOU Meter Revenue Meter+ 100A relays |
ยี่ห้อ: EMH |
โมเดล : NXT4 |
- Direct upto 120A,CT/5A 3ph4W, 3x230/400V,
- Integrated relay 100A acc to EN62055-31 and application class UC3
- Shock resistance or Impulse withstand voltage up to 12 KV
- Housing materials according to UL94 V 0 fire safety requirements
- Expandable with Variomod NXT modem
|
|
เอกสารเพิ่มเติม |
|
TOU Energy meter |
โมเดล : DIZ |
Specification
• Industry applications amd billing purposes with DIN rail mounting
• Compact design, only 6 pitch
• 4 tariffs, 4 quadrant meter, Power, Energy, v,a,w,var,pf,hz
• Industrial hi grade LCD Display with 8 digits + symbols • Digit height 4x6 mm • Transformer ratio Settable on location • PTB-approval
|
|
เอกสารเพิ่มเติม |
|
TOU Meter LZQJ XC |
โมเดล : LZQJ XC |
• TOU class 0.2, class 0.5 IEC62056-2,DLMS, Modbus
• 2xRS485, TCP/IP, GSM etc, optical interface
• Wide range input Voltage and current with Programmable CTPT ratio
• Wide range aux supply 48-300Vac/dc
• 3years memory every 15min
• 32 tariffs + 16 tariffless with each historical value
|
|
เอกสารเพิ่มเติม |
|
WH32…Pulse or RS485 |
• Phase loss with 3 x LED display for L1,L2,L3
• Pulse display with 2 x LED display for test & output
• Reverse direction display with LED
• Small modular size, DIN rail mounted.
• Easy installation to distribution boards, load center, miniature & etc.
by identifying where energy is being used.
• 7 digits LCD display with EEPROM displayable even power failure.
• Typical accuracy class 1.0 IEC1036
• 3Ph3W, 3Ph4W. Voltage 100V, 380V, 220/380V, 57.5/100V & etc.
• Current 1.5(6),5(30), 10(50), 15(90), 20(100), 5(40),5(100)A.
• Optional pulse output or RS485 for remote metering
• Tropical and Trivialized meters: 95% relative humidity.
|
|
เอกสารเพิ่มเติม |
|
WH31…Pulse |
• Phase loss with 3 x LED display for L1,L2,L3
• Pulse display with 2 x LED display for test & output
• Reverse direction display with LED
• Small modular size, DIN rail mounted.
• Easy installation to distribution boards, load center, miniature & etc.
by identifying where energy is being used.
• 6 digits mechanical displayable even power failure.
• Typical accuracy class 1.0 IEC1036
• 3Ph3W, 3Ph4W. Voltage 100V, 380V, 220/380V, 57.5/100V & etc.
• Current 1.5(6),5(30), 10(50), 15(90), 20(100), 5(40),5(100)A.
Optional pulse output or RS485 for remote meteringbr
• Tropical and Trivialized meters: 95% relative humidity.
|
|
เอกสารเพิ่มเติม |
|
WH12 …Pulse or RS485 |
• 1xLED display for Power ON and 1xLED display for Communication.
• 1xLED of Pulse display with infrared port
• Small modular size, DIN rail mounted, electrically isolated inputs
• Easy installation to distribution boards, load center, miniature & etc.
• Ideally suited for check metering and allocating costs.
• Meet the requirements of industrial, commercial, tertiary sectors
and Building by identifying where energy is being used.
• 7 digits with EEPROM displayable even power failure.
• Typical accuracy class 1.0 IEC1036
• Input current 2.5(10), 3(15), 5(30), 10(50), 20(100), 5(40), 5(100)
• Optional pulse output or RS485 for remote metering and billing
• meters: 95% relative humidity.
|
|
เอกสารเพิ่มเติม |
|
WH11 …Pulse |
• 1xLED display for Power ON
• 1xLED of Pulse output display
• Small modular size, DIN rail mounted, electrically isolated inputs
• Easy installation to distribution boards, load center, miniature & etc.
• Ideally suited for check metering and allocating costs.
• Meet the requirements of industrial, commercial, tertiary sectors
and Building by identifying where energy is being used.
• 6 digits cyclic numberic mechanical, displayable even power failure.
Input current 2.5(10), 3(15), 5(30), 10(50), 20(100), 5(40), 5(100)
• Optional pulse output or RS485 for remote metering and billing
• Tropicalised meters: 95% relative humidity.
|
|
เอกสารเพิ่มเติม |
|